Title page for ETD etd-04302012-143834


Type of Document Master's Thesis
Author Forrester, Michael Scott
Author's Email Address forreste@vt.edu
URN etd-04302012-143834
Title Assessing the Performance of HSPF When Using the High Water Table Subroutine to Simulate Hydrology in a Low-Gradient Watershed
Degree Master of Science
Department Biological Systems Engineering
Advisory Committee
Advisor Name Title
Benham, Brian L. Committee Chair
Kline, Karen S. Committee Member
McGuire, Kevin J. Committee Member
Keywords
  • uncertainty
  • modeling
  • high water table
  • HSPF
Date of Defense 2012-04-17
Availability unrestricted
Abstract
Modeling ground-water hydrology is critical in low-gradient, high water table watersheds where ground-water is the dominant contribution to streamflow. The Hydrological Simulation Program-FORTRAN (HSPF) model has two different subroutines available to simulate ground water, the traditional ground-water (TGW) subroutine and the high water table (HWT) subroutine. The HWT subroutine has more parameters and requires more data but was created to enhance model performance in low-gradient, high water table watershed applications. The objective of this study was to compare the performance and uncertainty of the TGW and HWT subroutines when applying HSPF to a low-gradient watershed in the Coastal Plain of northeast North Carolina. One hundred thousand Monte Carlo simulations were performed to generate data needed for model performance comparison. The HWT model generated considerably higher Nash-Sutcliffe efficiency (NSE) values while performing slightly worse when simulating the 50% lowest and 10% highest flows. Model uncertainty was assessed using the Average Relative Interval Length (ARIL) metric. The HWT model operated with more average uncertainty throughout all flow regimes. Based on the results, the HWT subroutine is preferable when applying HSPF to a low-gradient watershed and the accuracy of simulated stream discharge is important. In situations where a balance between performance and uncertainty is called for, the choice of which subroutine to employ is less clear cut.
Files
  Filename       Size       Approximate Download Time (Hours:Minutes:Seconds) 
 
 28.8 Modem   56K Modem   ISDN (64 Kb)   ISDN (128 Kb)   Higher-speed Access 
  Forrester_MS_T_2012.pdf 3.39 Mb 00:15:40 00:08:03 00:07:03 00:03:31 00:00:18
  Forrester_MS_T_2012_fairuse.pdf 116.06 Kb 00:00:32 00:00:16 00:00:14 00:00:07 < 00:00:01

Browse All Available ETDs by ( Author | Department )

dla home
etds imagebase journals news ereserve special collections
virgnia tech home contact dla university libraries

If you have questions or technical problems, please Contact DLA.